Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

09112 Corrosion Inhibition Challenges in a Mature Subsea Production Facility

Product Number: 51300-09112-SG
ISBN: 09112 2009 CP
Author: J. Collins, A. Leontieff, S. McKay, G. Duncan, D. Lasebikan, W. Mok
Publication Date: 2009
$0.00
$20.00
$20.00
A mature field located in UK sector of the North Sea, comprises one central platform with several subsea satellite tie-backs fabricated from carbon steel. Internal corrosion mitigation of these flowlines was based on the application of a combined scale/corrosion inhibitor. Following corrosion failures at the inlet sections (towhead) of the flowlines, the requirement for an effective inhibitor increased. Subsequent inspection of the towhead pipework revealed significant preferential weld corrosion. There had been improvements in inhibitor injection compliance; however, the selection of the incumbent inhibitor was based on limited performance test work.

An appraisal of the chemical injection system and a corrosion risk assessment of the flowlines highlighted short falls in the required corrosion management process. Rectifying the integrity issues involved significant economic, operational and technological challenges that had to be overcome to achieve continued integrity of the flowlines. Hardware upgrades of the chemical injection system were essential to deliver the high uptime required. Controlling preferential weld corrosion and growth rate of existing pits in a high shear stress environment was examined using a variety of novel corrosion testing techniques that mimic the corrosion morphology in the flowlines.

Keywords: corrosion failures, preferential weld corrosion, corrosion control, subsea flowline integrity, scale/corrosion inhibitor
A mature field located in UK sector of the North Sea, comprises one central platform with several subsea satellite tie-backs fabricated from carbon steel. Internal corrosion mitigation of these flowlines was based on the application of a combined scale/corrosion inhibitor. Following corrosion failures at the inlet sections (towhead) of the flowlines, the requirement for an effective inhibitor increased. Subsequent inspection of the towhead pipework revealed significant preferential weld corrosion. There had been improvements in inhibitor injection compliance; however, the selection of the incumbent inhibitor was based on limited performance test work.

An appraisal of the chemical injection system and a corrosion risk assessment of the flowlines highlighted short falls in the required corrosion management process. Rectifying the integrity issues involved significant economic, operational and technological challenges that had to be overcome to achieve continued integrity of the flowlines. Hardware upgrades of the chemical injection system were essential to deliver the high uptime required. Controlling preferential weld corrosion and growth rate of existing pits in a high shear stress environment was examined using a variety of novel corrosion testing techniques that mimic the corrosion morphology in the flowlines.

Keywords: corrosion failures, preferential weld corrosion, corrosion control, subsea flowline integrity, scale/corrosion inhibitor
Product tags
Also Purchased
Picture for 98057 INHIBITION OF SWEET CORROSION IN
Available for download

98057 INHIBITION OF SWEET CORROSION IN SUBSEA FLOWLINES

Product Number: 51300-98057-SG
ISBN: 98057 1998 CP
Author: M.J.J. Simon Thomas, P.B. Hebert, K.G. Jordan, S.E. Lorimer
$20.00
Picture for 96560 CORROSION CONTROL OF SUBSEA PIPING
Available for download

96560 CORROSION CONTROL OF SUBSEA PIPING SYSTEMS USING THERMAL SPRAYED ALUMINUM COATINGS

Product Number: 51300-96560-SG
ISBN: 96560 1996 CP
Author: S. L. Wolfson
$20.00
Picture for 09073 Installation of ROV-Friendly Cathodic Protection Retrofit Systems on Two Deepwater Subsea Deve
Available for download

09073 Installation of ROV-Friendly Cathodic Protection Retrofit Systems on Two Deepwater Subsea Developments

Product Number: 51300-09073-SG
ISBN: 09073 2009 CP
Author: Kim Thompson, James N. Britton, David Flanery and Peter Sandy
Publication Date: 2009
$20.00