Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

08641 Managing Sour Gas Corrosion: Testing, Design, Implementation and Field Results

Product Number: 51300-08641-SG
ISBN: 08641 2008 CP
Author: Sergio D. Kapusta, Damodaran Raghu, and Johnny Richards
Publication Date: 2008
$0.00
$20.00
$20.00
Natural gas is expected to make-up an increasing larger share of the worldwide energy supply. Many of the new gas fields are increasingly sour. The need to ensure safe production from these new fields means more emphasis on adequate materials selection and corrosion control. This paper provides an overview of the procedures that have been used over the past 16 years to manage sour gas corrosion risks at the Fairway Field, offshore Alabama. It covers the design, implementation, operation and monitoring of the corrosion control and asset integrity programs. The sour gas pipeline was inspected after 15 years in service, and found to be in practically "as new" condition. The produced water disposal pipeline experienced a leak, caused by internal corrosion, after 14 years in operation. Several factors that can affect the success or failure of a corrosion management program are discussed, in particular the ability of the corrosion control system to adapt to varying operational conditions, and to recover from unanticipated upsets.
Natural gas is expected to make-up an increasing larger share of the worldwide energy supply. Many of the new gas fields are increasingly sour. The need to ensure safe production from these new fields means more emphasis on adequate materials selection and corrosion control. This paper provides an overview of the procedures that have been used over the past 16 years to manage sour gas corrosion risks at the Fairway Field, offshore Alabama. It covers the design, implementation, operation and monitoring of the corrosion control and asset integrity programs. The sour gas pipeline was inspected after 15 years in service, and found to be in practically "as new" condition. The produced water disposal pipeline experienced a leak, caused by internal corrosion, after 14 years in operation. Several factors that can affect the success or failure of a corrosion management program are discussed, in particular the ability of the corrosion control system to adapt to varying operational conditions, and to recover from unanticipated upsets.
Product tags
Also Purchased
Picture for 08634 Materials and Corrosion History in LaBarge Madison Production: a 20 Year Success Story
Available for download

08634 Materials and Corrosion History in LaBarge Madison Production: a 20 Year Success Story

Product Number: 51300-08634-SG
ISBN: 08634 2008 CP
Author: Tim G. Martin, Joseph Bondos, and Stephen N. Smith
Publication Date: 2008
$20.00
Picture for 00139 FIT-FOR-PURPOSE MATERIALS TESTING FOR
Available for download

00139 FIT-FOR-PURPOSE MATERIALS TESTING FOR SOUR GAS SERVICE

Product Number: 51300-00139-SG
ISBN: 00139 2000 CP
Author: M. G. Hay
$20.00
Picture for 08104 A Review of Laboratory Evaluation Procedures for Materials Selection in Downhole Applications
Available for download

08104 A Review of Laboratory Evaluation Procedures for Materials Selection in Downhole Applications

Product Number: 51300-08104-SG
ISBN: 08104 2008 CP
Author: Robert D. Mack
Publication Date: 2008
$20.00