Search
Filters
Close

08227 Internal Inspection of 32" Red Hill Pipeline

Product Number: 51300-08227-SG
ISBN: 08227 2008 CP
Author: Terri Regin, Mike Denham, and Marco Campos
Publication Date: 2008
$0.00
$20.00
$20.00
The Red Hill complex consists of twenty 300,000 bbl underground storage tanks, three pipelines, and a pumping facility that was built between 1940 and 1945. The pipelines are located inside of an underground tunnel approximately 4.3 km (2.7 miles) long and 4.5 meters (15 feet) wide. This paper will discuss the project management and technical challenges for the metal loss inspection of the 813 mm (32-inch) diesel pipeline at Red Hill, FISC Pearl Harbor, HI. The pipeline has several “unpiggable” features such as 28 degree mitered bends, reduced valve sections and no launcher/receiver. Even though the pipeline is “above ground,” it rests directly on over 300 supports and is encased in over twenty bulk-heads, each four feet wide. The paper will discuss the project phases of (1) integrity assessment method tool selection, (2) planning, (3) fabrication of components, (4) mobilization, (5) installation of components, (6) cleaning, (7) in-line inspection, (8) demobilization, and (9) analysis.
The Red Hill complex consists of twenty 300,000 bbl underground storage tanks, three pipelines, and a pumping facility that was built between 1940 and 1945. The pipelines are located inside of an underground tunnel approximately 4.3 km (2.7 miles) long and 4.5 meters (15 feet) wide. This paper will discuss the project management and technical challenges for the metal loss inspection of the 813 mm (32-inch) diesel pipeline at Red Hill, FISC Pearl Harbor, HI. The pipeline has several “unpiggable” features such as 28 degree mitered bends, reduced valve sections and no launcher/receiver. Even though the pipeline is “above ground,” it rests directly on over 300 supports and is encased in over twenty bulk-heads, each four feet wide. The paper will discuss the project phases of (1) integrity assessment method tool selection, (2) planning, (3) fabrication of components, (4) mobilization, (5) installation of components, (6) cleaning, (7) in-line inspection, (8) demobilization, and (9) analysis.
Product tags
Also Purchased
Picture for 02082 PIPELINE INSPECTION/REHABILITATION...
Available for download

02082 PIPELINE INSPECTION/REHABILITATION DOCUMENTATION BEST PRACTICES

Product Number: 51300-02082-SG
ISBN: 02082 2002 CP
Author: Mark E. Olson
$20.00
Picture for 96052 ENHANCING PIPELINE INTEGRITY THROUGH
Available for download

96052 ENHANCING PIPELINE INTEGRITY THROUGH INTERNAL INSPECTION

Product Number: 51300-96052-SG
ISBN: 96052 1996 CP
Author: Dennis R. Turner
$20.00
Picture for 99525 ULTRASONIC CORROSION INSPECTION OF
Available for download

99525 ULTRASONIC CORROSION INSPECTION OF CRUDE OIL PIPELINE

Product Number: 51300-99525-SG
ISBN: 99525 1999 CP
Author: M. Kondo, M. Kobayashi and M. Kurashima
$20.00