Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

Use GIVING24 at checkout to save 20% on eCourses and books (some exclusions apply)!

02113 A User-Friendly Simulation Software for the Cathodic Protection of Large Networks of Buried Pipelines Influenced by DC-Traction Stray Currents

A simulation software for the cathodic protection (CP) of underground pipeline networks is presented. This software uses an advanced model for the coating quality, taking into account the local soil resistivity, holiday ratio, average holiday size, coating thickness and resistance.

Product Number: 51300-02113-SG
ISBN: 02113 2002 CP
Author: Leslie Bortels
$0.00
$20.00
$20.00

A simulation software for the cathodic protection (CP) of underground pipeline networks is presented. This software uses an advanced model for the coating quality, taking into account the local soil resistivity, holiday ratio, average holiday size, coating thickness and resistance. The model considers the ohmic voltage drop in the pipes and integrates aboveground structures like rail bars, sub-stations, electric trains or trams and overhead wires. As a result the model gives the pipe- to-soil potentials along a pipe, the axial currents flowing through the pipes as well as the radial current densities leaving or entering the pipe walls. The software can deal with all standard kinds of cathodic protection interferences as well as stray currents coming from other CP installations, DC-traction systems, HVDC transmission lines, earthing systems and others. A complex situation with railways interference is investigated and it is found that the numerical calculations are confirmed by qualitative observations.

A simulation software for the cathodic protection (CP) of underground pipeline networks is presented. This software uses an advanced model for the coating quality, taking into account the local soil resistivity, holiday ratio, average holiday size, coating thickness and resistance. The model considers the ohmic voltage drop in the pipes and integrates aboveground structures like rail bars, sub-stations, electric trains or trams and overhead wires. As a result the model gives the pipe- to-soil potentials along a pipe, the axial currents flowing through the pipes as well as the radial current densities leaving or entering the pipe walls. The software can deal with all standard kinds of cathodic protection interferences as well as stray currents coming from other CP installations, DC-traction systems, HVDC transmission lines, earthing systems and others. A complex situation with railways interference is investigated and it is found that the numerical calculations are confirmed by qualitative observations.

PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 05243 Dynamic Stray Current Analysis for New DC
Available for download

05243 Dynamic Stray Current Analysis for New DC Powered Transit Systems

Product Number: 51300-05243-SG
ISBN: 05243 2005 CP
Author: Kenneth J. Moody, Parsons Brinckerhoff
$20.00