Search
Filters
Close

Save 20% on select titles with code HIDDEN24 - Shop The Sale Now

01582 USING THE 100 mV CRITERION IN INDUSTRIAL AND SIMILAR FACILITIES

Product Number: 51300-01582-SG
ISBN: 01582 2001 CP
Author: Tony Rizk and John H. Fitzgerald III
$0.00
$20.00
$20.00
Industrial and other commercial facilities often require installing cathodic protection on non isolated structures such as chilled water lines, bare piping of various types and underground storage tanks. Often, because of the large amount of metal that is interconnected to the protected structures, the 100mV cathodic protection criterion is the only one that is practicable. This paper describes the testing required for this criterion, half cell placement, determination of the formation or decay of polarization and the accuracy of taking IR drop flee ("instant off') readings. Case histories concerning a large industrial plant, a gasoline service station and a sewage lift station are described Keywords: cathodic protection criteria, gasoline service stations, industrial plants, one hundred mV polarization, retrofitting cathodic protection, sewage lift stations
Industrial and other commercial facilities often require installing cathodic protection on non isolated structures such as chilled water lines, bare piping of various types and underground storage tanks. Often, because of the large amount of metal that is interconnected to the protected structures, the 100mV cathodic protection criterion is the only one that is practicable. This paper describes the testing required for this criterion, half cell placement, determination of the formation or decay of polarization and the accuracy of taking IR drop flee ("instant off') readings. Case histories concerning a large industrial plant, a gasoline service station and a sewage lift station are described Keywords: cathodic protection criteria, gasoline service stations, industrial plants, one hundred mV polarization, retrofitting cathodic protection, sewage lift stations
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 01581 ORIGIN AND VALIDATION OF THE 100 mV
Available for download

01581 ORIGIN AND VALIDATION OF THE 100 mV POLARIZATION CRITERION

Product Number: 51300-01581-SG
ISBN: 01581 2001 CP
Author: Thomas J. Barlo
$20.00
Picture for 08072 The Use of the 100 mV Polarization Criterion in Complex Facilities
Available for download

08072 The Use of the 100 mV Polarization Criterion in Complex Facilities

Product Number: 51300-08072-SG
ISBN: 08072 2008 CP
Author: Whitt L. Trimble
Publication Date: 2008
$20.00
Picture for 01592 100 mV POLARIZATION CRITERION AND EXTERNAL
Available for download

01592 100 mV POLARIZATION CRITERION AND EXTERNAL SCC OF UNDERGROUND PIPELINES

Product Number: 51300-01592-SG
ISBN: 01592 2001 CP
Author: J. A. Beavers and K. C. Garrity
$20.00