01271 Field Sidestream Investigations of Corrosion Control Using Regenerative Biofilms (CCURB)

Product Number: 51300-01271-SG
ISBN: 02171 2001 CP
Author: Kirsten Trandem, Z. Shadi Farhangrazi, Thomas K. Wood, Peggy J. Arps, and James C. Earthman
$0.00
$20.00
$20.00
Closed-loop sidestream systems that simulate cooling water conditions are being used to investigate corrosion control using regenerative biofilms (CCURB) at the UC Irvine Central Generating Facility. The closed-loop operation avoids possible ground loop problems associated with electrochemical measurements and permits the investigation of bacterial treatments prior to approval for use in the target service water systems. These treatments are being developed as alternatives to the use of biocides and inhibitors for controlling corrosion. Electrochemical impedance spectroscopy and mass loss measurements were performed with coupons and pipe samples of 1018 mild steel under different flow conditions in service water that was inoculated with engineered bacteria. A comparison of these results with those for samples simultaneously exposed to unaltered service water indicates that the engineered bacteria significantly reduce the corrosion rate of mild steel under service water conditions. It was also noted that corrosion control by the engineered bacteria was less effective for samples that were installed at the time of inoculation as opposed to those pre-exposed to unaltered service water. Furthermore, the addition of supplemental nutrients did not enhance the corrosion control by the engineered bacteria.
Closed-loop sidestream systems that simulate cooling water conditions are being used to investigate corrosion control using regenerative biofilms (CCURB) at the UC Irvine Central Generating Facility. The closed-loop operation avoids possible ground loop problems associated with electrochemical measurements and permits the investigation of bacterial treatments prior to approval for use in the target service water systems. These treatments are being developed as alternatives to the use of biocides and inhibitors for controlling corrosion. Electrochemical impedance spectroscopy and mass loss measurements were performed with coupons and pipe samples of 1018 mild steel under different flow conditions in service water that was inoculated with engineered bacteria. A comparison of these results with those for samples simultaneously exposed to unaltered service water indicates that the engineered bacteria significantly reduce the corrosion rate of mild steel under service water conditions. It was also noted that corrosion control by the engineered bacteria was less effective for samples that were installed at the time of inoculation as opposed to those pre-exposed to unaltered service water. Furthermore, the addition of supplemental nutrients did not enhance the corrosion control by the engineered bacteria.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 01272 CORROSION CONTROL USING REGENERATIVE
Available for download

01272 CORROSION CONTROL USING REGENERATIVE BIOFILMS (CCURB) - AN OVERVIEW

Product Number: 51300-01272-SG
ISBN: 01272 2001 CP
Author: Barry C. Syrett, Thomas K. Wood, Florian Mansfeld, James C. Earthman and Peggy J. Arps
$20.00
Picture for 01281 APPLICATIONS OF GLUTARALDEHYDE
Available for download

01281 APPLICATIONS OF GLUTARALDEHYDE IN THE CONTROL OF MIC

Product Number: 51300-01281-SG
ISBN: 01281 2001 CP
Author: G.A. Ganzer, D.B. McIlwaine, J.A. Diemer, M. Freid, M. Russo
$20.00
Picture for 01277 BIOFILM CONTROL WITH BROMO-CHLORO-
Available for download

01277 BIOFILM CONTROL WITH BROMO-CHLORO-DIMETHYL-HYDANTOIN

Product Number: 51300-01277-SG
ISBN: 01277 2001 CP
Author: Jeffrey F. Kramer
$20.00