00810 ANODES FOR CATHODIC PROTECTION Of REINFORCED CONCRETE

Product Number: 51300-00810-SG
ISBN: 00810 2000 CP
Author: S.J. Bullard, B.S. Covino, Jr., S.D. Cramer, G.R. Holcomb, J.H. Russell, C.B. Cryer and H.M. Laylor
Industry: Highways & Bridges
$0.00
$20.00
$20.00
Consumable anodes were evaluated in the laboratory for use in cathodic protection systems for steel reinforced concrete bridges in coastal environments and in areas where deicing salts are employed. The anode materials included Zn-hydrogel and thermal-sprayed Zn, Zn-15A1 and Al-12Zn-0.2In. These anodes were evaluated for service in both galvanic (GCP) and impressed current (ICCP) cathodic protection systems. ICCP anodes were electrochemically aged at a factor of 15 times greater than used by the Oregon Department of Transportation in typical coastal ICCP systems (2.2 mA/m 2 based on anode area). Increasing moisture at the anode-concrete interface reduced the operating voltage of all the anodes. The pH at the anode-concrete interface fell to 7 to 8.5 with electrochemical age. Bond strength between the anodes and concrete decreased with electrochemical aging. Interfacial chemistry was the critical link between long-term anode performance and electrochemical age. Zn-hydrogel and thermal-sprayed Zn and Al-12Zn-0.2In GCP anodes appear to supply adequate protection current to rebar in the Cape Perpetua Viaduct. Keywords: bridge, cathodic protection, ICCP, GCP, reinforced concrete, bond strength, electrochemical aging, thermal-spray, arc-spray, zinc, aluminum, indium, zinc-hydrogel.
Consumable anodes were evaluated in the laboratory for use in cathodic protection systems for steel reinforced concrete bridges in coastal environments and in areas where deicing salts are employed. The anode materials included Zn-hydrogel and thermal-sprayed Zn, Zn-15A1 and Al-12Zn-0.2In. These anodes were evaluated for service in both galvanic (GCP) and impressed current (ICCP) cathodic protection systems. ICCP anodes were electrochemically aged at a factor of 15 times greater than used by the Oregon Department of Transportation in typical coastal ICCP systems (2.2 mA/m 2 based on anode area). Increasing moisture at the anode-concrete interface reduced the operating voltage of all the anodes. The pH at the anode-concrete interface fell to 7 to 8.5 with electrochemical age. Bond strength between the anodes and concrete decreased with electrochemical aging. Interfacial chemistry was the critical link between long-term anode performance and electrochemical age. Zn-hydrogel and thermal-sprayed Zn and Al-12Zn-0.2In GCP anodes appear to supply adequate protection current to rebar in the Cape Perpetua Viaduct. Keywords: bridge, cathodic protection, ICCP, GCP, reinforced concrete, bond strength, electrochemical aging, thermal-spray, arc-spray, zinc, aluminum, indium, zinc-hydrogel.
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 00812 HUMECTANT USE IN THE CATHODIC PROTECTION
Available for download

00812 HUMECTANT USE IN THE CATHODIC PROTECTION OF REINFORCED CONCRETE

Product Number: 51300-00812-SG
ISBN: 00812 2000 CP
Author: J. E. Bennett, H. M. Laylor, G. R. Holcomb, B. S. Covino, Jr., J. H. Russell, S. J. Bullard, S. D. C
$20.00
Picture for 00794 EIS MEASUREMENTS ON CATHODICALLY PROTECTED
Available for download

00794 EIS MEASUREMENTS ON CATHODICALLY PROTECTED STEEL IN CONCRETE

Product Number: 51300-00794-SG
ISBN: 00794 2000 CP
Author: M.A. Talavera, T. Perez and J. Genesca
$20.00
Picture for 00791 RESULTS OF LONG TERM MONITORING OF
Available for download

00791 RESULTS OF LONG TERM MONITORING OF CORROSION INHIBITORS APPLIED TO CORRODING REINFORCED CONCRETE STRUCURES

Product Number: 51300-00791-SG
ISBN: 00791 2000 CP
Author: John P. Broomfield
$20.00