Server maintenance is scheduled for Saturday, December 21st between 6am-10am CST.

During that time, parts of our website will be affected until maintenance is completed. Thank you for your patience.

Search
Filters
Close

51316-7797-Interference between sacrificial CP systems

Product Number: 51316-7797-SG
ISBN: 7797 2016 CP
Author: Tim Froome
Publication Date: 2016
$0.00
$20.00
$20.00
It is generally accepted that destructive interference can occur between impressed and sacrificial cathodic protection systems which can result in difficulty with control of the ICCP system and which can also cause problems with performance of the sacrificial CP systemLess well known is the possibility of interference between multiple sacrificial CP systems. Such interference can occur under a number of different circumstances and may for example arise when different design approaches are used for sub-structures which are then to be integrated together. Each CP system may be competently designed for stand-alone operation but when combined together protection potentials and life of the systems may be affected by interference. Consequences may include early consumption of anodes and more positive potentials towards end of life.Such effects can readily occur when different types of anode material are used but may also occur when anodes in both CP systems are made from the same anode material.This paper shows how mathematical modelling has been used to simulate performance of both stand-alone and integrated sacrificial systems. It goes on to identify interference effects between such systems and investigates a number of different situations in which destructive interference can occur. Conclusions are reached of practices that can be adopted to avoid such destructive interference.
It is generally accepted that destructive interference can occur between impressed and sacrificial cathodic protection systems which can result in difficulty with control of the ICCP system and which can also cause problems with performance of the sacrificial CP systemLess well known is the possibility of interference between multiple sacrificial CP systems. Such interference can occur under a number of different circumstances and may for example arise when different design approaches are used for sub-structures which are then to be integrated together. Each CP system may be competently designed for stand-alone operation but when combined together protection potentials and life of the systems may be affected by interference. Consequences may include early consumption of anodes and more positive potentials towards end of life.Such effects can readily occur when different types of anode material are used but may also occur when anodes in both CP systems are made from the same anode material.This paper shows how mathematical modelling has been used to simulate performance of both stand-alone and integrated sacrificial systems. It goes on to identify interference effects between such systems and investigates a number of different situations in which destructive interference can occur. Conclusions are reached of practices that can be adopted to avoid such destructive interference.
Product tags
Also Purchased
Picture for Assessing Interference Between Sacrificial Anodes on Anode Sleds
Available for download

51313-02344-Assessing Interference Between Sacrificial Anodes on Anode Sleds

Product Number: 51313-02344-SG
ISBN: 02344 2013 CP
Author: Tim Froome
Publication Date: 2013
$20.00
Picture for 09545 Interference of an Impressed CP System with an Adjacent Sacrificial CP System and its Mitigati
Available for download

09545 Interference of an Impressed CP System with an Adjacent Sacrificial CP System and its Mitigation

Product Number: 51300-09545-SG
ISBN: 09545 2009 CP
Author: Fawzi S. AL-Madani, Ezeddin R. Busba, David Scantlebury and Hussain S. Boshalla
Publication Date: 2009
$20.00