In this study, enamel-coated steel pipe samples with various levels of cathodic protection were tested to investigate their impedance models by electrochemical impedance spectroscopy (EIS).
Cathodic protection (CP) integrated with a protective barrier (e.g., thick organic coating) has been widely applied for the corrosion protection of steel pipelines. However, CP may make the pipe-coating interface become a more alkaline environment, potentially leading to cathodic delamination of the coating. It is, therefore, essential to evaluate the compatibility of new coating with CP in steel pipeline applications. Porcelain enamel, as an inorganic coating material, is widely used in chemical reactors, heat exchangers, or food-processing vessels due to its excellent engineering properties such as high abrasion, corrosion, and heat resistances. In this study, enamel-coated steel pipe samples with various levels of cathodic protection were tested to investigate their impedance models by electrochemical impedance spectroscopy (EIS). One electrical equivalent circuit (EEC) models were used to fit the EIS data of coated samples without CP, while two EEC models were employed for samples with CP. Coating capacitance was used to investigate the water absorption characteristic in coating. Through scanning electron microscopy (SEM), no corrosion products and delamination of enamel coating were found at the interface of steel substrate and enamel coating due to its chemical bond with metal substrates.
Key words: Pipeline steel; enamel coating; scanning electron microscopy (SEM); cathodic protection (CP); electrochemical impedance spectroscopy (EIS).
The paper discusses “past” developments, “present” status, and “future” advancements of inspection, monitoring, and modelling technologies.
We are unable to complete this action. Please try again at a later time.
If this error continues to occur, please contact AMPP Customer Support for assistance.
Error Message:
Please login to use Standards Credits*
* AMPP Members receive Standards Credits in order to redeem eligible Standards and Reports in the Store
You are not a Member.
AMPP Members enjoy many benefits, including Standards Credits which can be used to redeem eligible Standards and Reports in the Store.
You can visit the Membership Page to learn about the benefits of membership.
You have previously purchased this item.
Go to Downloadable Products in your AMPP Store profile to find this item.
You do not have sufficient Standards Credits to claim this item.
Click on 'ADD TO CART' to purchase this item.
Your Standards Credit(s)
1
Remaining Credits
0
Please review your transaction.
Click on 'REDEEM' to use your Standards Credits to claim this item.
You have successfully redeemed:
Go to Downloadable Products in your AMPP Store Profile to find and download this item.
Metallurgical investigations on a welded sample of 25% Cr super duplex stainless steel (UNS S32750) from a vessel that had operated above 300-350°C (570-660°F) for six months, resulting in brittle fracture.
A case study is presented for the Life Cycle Costing (LCC) analysis to quantify and compare different corrosion mitigation methods. Strategies to minimize the costs due to corrosion are included.