High Resolution CT Scan as Tool for Precise Quantification of Material Loss due to Localized Corrosion in Brake Calipers

Product Number: 51321-16467-SG
Author: Marco Bandiera/Andrea Bonfanti/Federico Bertasi/Alessandro Mancini
Publication Date: 2021
$0.00
$20.00
$20.00

The evaluation of the extension and the magnitude of localized corrosion phenomena such as pitting and crevice corrosion occurring in brake calipers is usually performed by standard metallographic analysis. This approach can provide only bi-dimensional and qualitative information with a poor relevance both in terms of description of the failures and of prediction of corrosion trends. For this reason, in this work an experimental approach based on the high-resolution X-Ray Computed Tomography analysis (CT-Scan) is proposed, showing the potentiality of this non-destructive technique as a tridimensional probe for the precise quantification of material loss due to localized corrosion phenomena in braking calipers. Examples are reported both on laboratory specimens and on real calipers. Finally, the volumetric extension of material loss is correlated with corrosion rates calculated using voltammetry techniques thus providing a direct link between ex situ and in situ methods.

Key words: Localized Corrosion, Pitting, CT-Scan, Failure Analysis, Material Loss Rate, Voltammetry, Braking System

The evaluation of the extension and the magnitude of localized corrosion phenomena such as pitting and crevice corrosion occurring in brake calipers is usually performed by standard metallographic analysis. This approach can provide only bi-dimensional and qualitative information with a poor relevance both in terms of description of the failures and of prediction of corrosion trends. For this reason, in this work an experimental approach based on the high-resolution X-Ray Computed Tomography analysis (CT-Scan) is proposed, showing the potentiality of this non-destructive technique as a tridimensional probe for the precise quantification of material loss due to localized corrosion phenomena in braking calipers. Examples are reported both on laboratory specimens and on real calipers. Finally, the volumetric extension of material loss is correlated with corrosion rates calculated using voltammetry techniques thus providing a direct link between ex situ and in situ methods.

Key words: Localized Corrosion, Pitting, CT-Scan, Failure Analysis, Material Loss Rate, Voltammetry, Braking System

Also Purchased
Picture for Successful Application of MP-ICDA to Assess and Confirm Crude Oil Pipeline Corrosion Threats in Kuwait using ILI
Available for download

Successful Application of MP-ICDA to Assess and Confirm Crude Oil Pipeline Corrosion Threats in Kuwait using ILI

Product Number: 51321-16271-SG
Author: Amer Jaragh/ShabbirSafri/PatrickJ. Teevens/MilesHuynh/TijanPinnock/AshishKhera
Publication Date: 2021
$20.00
Picture for Compatibility of Polymers Exposed to Heating Oil Blends With 10 % and 20 % Biodiesel (FAME)
Available for download

Compatibility of Polymers Exposed to Heating Oil Blends With 10 % and 20 % Biodiesel (FAME)

Product Number: 51321-16222-SG
Author: Sina Pötzsch/Ralph Bäßler/Margit Weltschev
Publication Date: 2021
$20.00