51312-01488-EFFECT OF TROPICAL ENVIRONMENT IN TRANSMISSION TOWERS

Product Number: 51312-01488-SG
ISBN: 01488 2012 CP
Author: Oladis Troconis de Rincon
Publication Date: 2012
$0.00
$20.00
$20.00
This paper presents the results of the evaluation diagnosis and repair procedures of galvanized transmission towers localized in a very aggressive tropical marine environment (> C5 ISO 9223). Initially it shows an estimate of the damage in magnitude and extent of all the towers after five years of construction based on a detailed inspection of two of them and the inspection of a sample of the rest of them. This latter based on a probabilistic analysis with 95% confidence. All this work allowed to determine the towers with the highest amount of damage being them the suggested to be repaired first. In the case of the fasteners very important pieces to maintain the stability of the different elements of the tower it was determined (with the same reliability of 95%) the quantity of fasteners to be replaced immediately because of their high degradation (bolts with total loss of the galvanized treatment and severe corrosion of the steel base). It is important to point out that this study allowed to quantify all the bolts that need to be replaced per tower which at the present time is estimated to be over 20% per tower and more than 31% per trunk. Taking into consideration the previous analysis and the environmental data it can be said that the area where these towers are located is very aggressive. Therefore coated galvanized steel must be used instead of non-coated galvanized steel.
This paper presents the results of the evaluation diagnosis and repair procedures of galvanized transmission towers localized in a very aggressive tropical marine environment (> C5 ISO 9223). Initially it shows an estimate of the damage in magnitude and extent of all the towers after five years of construction based on a detailed inspection of two of them and the inspection of a sample of the rest of them. This latter based on a probabilistic analysis with 95% confidence. All this work allowed to determine the towers with the highest amount of damage being them the suggested to be repaired first. In the case of the fasteners very important pieces to maintain the stability of the different elements of the tower it was determined (with the same reliability of 95%) the quantity of fasteners to be replaced immediately because of their high degradation (bolts with total loss of the galvanized treatment and severe corrosion of the steel base). It is important to point out that this study allowed to quantify all the bolts that need to be replaced per tower which at the present time is estimated to be over 20% per tower and more than 31% per trunk. Taking into consideration the previous analysis and the environmental data it can be said that the area where these towers are located is very aggressive. Therefore coated galvanized steel must be used instead of non-coated galvanized steel.
Product tags
Also Purchased
Picture for Corrosion rates of carbon steel in confined environments
Available for download

51312-01495-Corrosion rates of carbon steel in confined environments

Product Number: 51312-01495-SG
ISBN: 01495 2012 CP
Author: Adam Rubin
Publication Date: 2012
$20.00
Picture for Measurement and prediction of corrosion damage in stainless steels in nitric acid containing oxidizi
Available for download

51312-01487-Measurement and prediction of corrosion damage in stainless steels in nitric acid containing oxidizi

Product Number: 51312-01487-SG
ISBN: 01487 2012 CP
Author: V. Kain
Publication Date: 2012
$20.00
Picture for ELECTROCHEMICAL ASSESSMENT OF CORROSION BEHAVIOR OF 316 STAINLESS STEEL IN SODIUM CHLORATE SOLUTIONS
Available for download

51312-01489-ELECTROCHEMICAL ASSESSMENT OF CORROSION BEHAVIOR OF 316 STAINLESS STEEL IN SODIUM CHLORATE SOLUTIONS

Product Number: 51312-01489-SG
ISBN: 01489 2012 CP
Author: Lester M. Dobosz
Publication Date: 2012
$20.00