Search
Filters
Close

Durability Assessment of Reinforced-SHCC Structures During Initiation and Propagation Phases of Corrosion

Product Number: 51321-16491-SG
Author: Hamidreza Fakhri/ Kenneth L. Fishman/Ravi Ranade
Publication Date: 2021
$0.00
$20.00
$20.00

The fundamental reason behind the corrosion-related deteriorations in reinforced concrete structures is the brittleness of conventional concrete, which makes the unreinforced cover prone to cracking under small tensile stresses. Unlike conventional concrete, Strain-Hardening Cementitious Composite (SHCC) has been shown to mitigate the corrosion-related damage, primarily in the propagation phase of corrosion, due to small crack widths typically limited under 100 μm. This paper summarizes important findings from an extensive study, which evaluated the corrosion protection offered by SHCC during both the initiation and the propagation phases of corrosion, and compared its effectiveness to that of conventional concrete. The experimental investigations led to the development of a novel method for identifying the critical chloride concentration (Ccrit) that is vital for determining the time-to-corrosion initiation. The novel method and additional investigations on the performance of reinforced-SHCC specimens during accelerated corrosion tests (propagation phase) provide a clearer assessment of the durability of cement-based composite structures.

Keywords: reinforced concrete, strain-hardening cementitious composite, engineered cementitious composite, corrosion, critical chloride content, chloride diffusion, macro-cell current, accelerated corrosion test, passive film

The fundamental reason behind the corrosion-related deteriorations in reinforced concrete structures is the brittleness of conventional concrete, which makes the unreinforced cover prone to cracking under small tensile stresses. Unlike conventional concrete, Strain-Hardening Cementitious Composite (SHCC) has been shown to mitigate the corrosion-related damage, primarily in the propagation phase of corrosion, due to small crack widths typically limited under 100 μm. This paper summarizes important findings from an extensive study, which evaluated the corrosion protection offered by SHCC during both the initiation and the propagation phases of corrosion, and compared its effectiveness to that of conventional concrete. The experimental investigations led to the development of a novel method for identifying the critical chloride concentration (Ccrit) that is vital for determining the time-to-corrosion initiation. The novel method and additional investigations on the performance of reinforced-SHCC specimens during accelerated corrosion tests (propagation phase) provide a clearer assessment of the durability of cement-based composite structures.

Keywords: reinforced concrete, strain-hardening cementitious composite, engineered cementitious composite, corrosion, critical chloride content, chloride diffusion, macro-cell current, accelerated corrosion test, passive film

Also Purchased
Picture for 03051 FIELD PERFORMANCE VERSUS LABORATORY
Available for download

03051 FIELD PERFORMANCE VERSUS LABORATORY TESTING: A STUDY OF EPOXY TANK AND VESSEL LININGS USED IN THE CANADIAN OIL PATCH

Product Number: 51300-03051-SG
ISBN: 03051 2003 CP
Author: Mike O’Donoghue, Ph.D., Ron Garrett, Jamie Garrett, Linda G.S. Gray and Brent Drader
$20.00
Picture for 01421 AN FRP SPECIFICATIONS GENERATION
Available for download

01421 AN FRP SPECIFICATIONS GENERATION TOOL FOR BLEACH PLANT TANKS AND TOWERS

Product Number: 51300-01421-SG
ISBN: 01421 2001 CP
Author: Jerome L. DeVilbiss
$20.00
Picture for 01407 DESIGN, FABRICATION, TRANSPORTATION,
Available for download

01407 DESIGN, FABRICATION, TRANSPORTATION, AND TESTING OF A 60,000-GALLON DUAL LAMINATE TANK FOR HOT CAUSTIC

Product Number: 51300-01407-SG
ISBN: 01407 2001 CP
Author: Joseph M. Lassandro
$20.00