Search
Filters
Close

51318-10955-CP shielding effect on buried pipeline by complex bridge structure

Cathodic Protection of a 57 km long pipeline section requires a few milliAmps of CP current. A new motorway bridge is built above the pipeline causing a potential risk of shielding the low cathodic current.

Product Number: 51318-10955-SG
Author: Christophe Baeté / Nick Kioupis
Publication Date: 2018
$0.00
$20.00
$20.00

Cathodic Protection is an effective method for protecting coating defects on buried pipelines if sufficient current reaches the pipeline surface. In the presence of nearby foundations shielding effects may occur by the construction constraint.

A case is discussed of a 57 km long 30 inch 3L-PE coated high pressure natural pipeline section requiring a few milliAmps of CP current that is provided by a single voltage controlled rectifier. The current density is in the range of 0.09A/m2 only. Halfway the trajectory a new 420 m long motorway bridge structure is built above the pipeline. In total 498 concrete reinforced foundation piles are aligned along the pipeline causing a potential risk of shielding the low cathodic current at that particular location. In addition the pipeline is connected to the bridge structure by an anchoring system for stabilization purposes during settlement of the bridge structure after construction. The anchor positions are susceptible locations where significant coating damage may occur on the short or longer term.

The degree of shielding effect was validated with FEM based modeling. The protection level of the pipeline and the DCVG sensitivity was computed for various scenarios. Modeling illustrated the CP current path around the pipeline and the foundation piles. The contribution of the rebar structure of the piles was accounted for as well.

Key words: CP shielding, concrete bridge structure, computational modeling

Cathodic Protection is an effective method for protecting coating defects on buried pipelines if sufficient current reaches the pipeline surface. In the presence of nearby foundations shielding effects may occur by the construction constraint.

A case is discussed of a 57 km long 30 inch 3L-PE coated high pressure natural pipeline section requiring a few milliAmps of CP current that is provided by a single voltage controlled rectifier. The current density is in the range of 0.09A/m2 only. Halfway the trajectory a new 420 m long motorway bridge structure is built above the pipeline. In total 498 concrete reinforced foundation piles are aligned along the pipeline causing a potential risk of shielding the low cathodic current at that particular location. In addition the pipeline is connected to the bridge structure by an anchoring system for stabilization purposes during settlement of the bridge structure after construction. The anchor positions are susceptible locations where significant coating damage may occur on the short or longer term.

The degree of shielding effect was validated with FEM based modeling. The protection level of the pipeline and the DCVG sensitivity was computed for various scenarios. Modeling illustrated the CP current path around the pipeline and the foundation piles. The contribution of the rebar structure of the piles was accounted for as well.

Key words: CP shielding, concrete bridge structure, computational modeling

Also Purchased