This paper describes the experience gained in “corrosion monitoring” in the overhead systems of three crude distillation units of a refinery in Haifa, Israel. The data of electrical resistance (ER) probes, connected to an on-line data acquisition system were compared with the mass loss method and chemical analysis of accumulated sour water tier condensation in the overhead system. SEM & EDS analysis of films and deposits formed on the coupons showed that iron sulfide with impurities of chlorides are responsible for the comosion extent. The corrosion was
less than 5 MPY when a uniform tenacious iron sulfide films of 10-50 microns thickness were formed. The severe corrosion occurred when deposits and non-uniform films of more than 80- 100 microns thickness were formed. Special attention was given to ER probes which were connected on-line to the process units and enabled the operators to react immediately to any change in corrosion rates.
KEYWORDS: corrosion monitoring, crude distillation unit, mass loss method (coupons), electrical resistance (ER) probes, on-line corrosion monitoring system, Distributed Control System (DCS), accumulated condensed sour water.