Alloy 22 (N06022) is a nickel base alloy especially designed to resist all forms of industrial corrosion. In aggressive environmental conditions and in the presence of tight occluded conditions, Alloy 22 could suffer crevice corrosion, a form of localized attack. The likelihood of crevice corrosion is governed by the values of the critical potential (Ecrit) for crevice corrosion and the corrosion potential (Ecorr). If Ecrit is higher than Ecorr crevice corrosion will not occur. The objective of this work was to explore the effect of the electrolyte temperature and pH on the value of Ecorr for Alloy 22. Results show that the Ecorr was lower for alkaline simulated concentrated ground water than for acidified simulated concentrated ground water solutions. For the acidified simulated ground water solution the Ecorr increased with the temperature probably because a more protective and passivating oxide film was established at the higher temperatures.

Keywords: N06022, corrosion potential, pH, temperature, simulated concentrated ground water
Alloy 22 (N06022) is a nickel base alloy especially designed to resist all forms of industrial corrosion. In aggressive environmental conditions and in the presence of tight occluded conditions, Alloy 22 could suffer crevice corrosion, a form of localized attack. The likelihood of crevice corrosion is governed by the values of the critical potential (Ecrit) for crevice corrosion and the corrosion potential (Ecorr). If Ecrit is higher than Ecorr crevice corrosion will not occur. The objective of this work was to explore the effect of the electrolyte temperature and pH on the value of Ecorr for Alloy 22. Results show that the Ecorr was lower for alkaline simulated concentrated ground water than for acidified simulated concentrated ground water solutions. For the acidified simulated ground water solution the Ecorr increased with the temperature probably because a more protective and passivating oxide film was established at the higher temperatures.

Keywords: N06022, corrosion potential, pH, temperature, simulated concentrated ground water
Product tags
Also Purchased
Picture for 10237 Crevice Corrosion Repassivation of Alloy 22 in Chloride Solutions
Available for download

10237 Crevice Corrosion Repassivation of Alloy 22 in Chloride Solutions

Product Number: 51300-10237-SG
ISBN: 10237 2010 CP
Author: Martin A. Rodriguez, Mauricio Rincón Ortiz, Ricardo M. Carranza and Raul B. Rebak
Publication Date: 2010
$20.00
Picture for 06626 INHIBITION OF CHLORIDE INDUCED CREVICE
Available for download

06626 INHIBITION OF CHLORIDE INDUCED CREVICE CORROSION IN ALLOY 22 BY FLUORIDE IONS

Product Number: 51300-06626-SG
ISBN: 06626 2006 CP
Author: Ricardo M. Carranza, Martin A. Rodriguez, Raul B. Rebak
$20.00
Picture for 07581 Environmental and Geometrical Conditions to Sustain Crevice in Alloy 22
Available for download

07581 Environmental and Geometrical Conditions to Sustain Crevice in Alloy 22

Product Number: 51300-07581-SG
ISBN: 07581 2007 CP
Author: Ricardo M. Carranza, Martin A. Rodriguez, and Raul B. Rebak
Publication Date: 2007
$20.00