The simultaneous fluctuations of potential noise and current noise between two nominally identical X-
65 mild steel electrodes were recorded in deaerated aqueous sodium chloride solutions with
concentration ranging between 1 and 20 wt % at 80oC. Electrochemical noise (EN) was obtained from
both 11.6 cm2 and 1 cm2 coupons in 1 wt % NaCl solution to learn how the surface area affects EN
measurements. Only small surface area coupons (1 cm2) were used in 10 wt % and 20 wt % NaCl
solution experiments to understand the role of Cl- on localized corrosion processes. Linear polarization
resistance measurements were conducted in each experiment to investigate the general corrosion
behavior. The surface morphology of coupons was observed with a scanning electrochemical
microscope (SEM). The results showed that the electrode area influenced the EN signal. Transients
related to metastable pitting were best observed with 1 cm2 coupons in 1, 10, and 20 wt % NaCl
solutions, but such transients were not clearly obtained for 11.6 cm2 coupons in the 1 wt % NaCl
solution. Both statistical analysis of recorded current and potential noise and SEM analysis showed that
increasing the NaCl solution concentration did not change the localized corrosion rate.
Keywords: Localized CO2 corrosion, mild steel, electrochemical noise, electrode size, NaCl
concentration