In presence of stray current interference due to DC transit systems, CP is operated at so-called “constant potential” condition. This technique consists of a continuous measurement of the pipeline potential by a fixed reference electrode, and the use of such measured potential to pilot the feeder dynamically, in order to maintain that potential constant. An accurate analysis of this technique reveals that what is maintained constant is IR drop in soil rather than the true potential of the structure. On the basis of this evidence, a new approach was investigated, consisting on two steps: the first was the measurement of the true potential by means of a corrosion coupon with an embedded reference electrode, to check protection conditions, and the second was the measurement of the coupon current. The innovation consists of the use of such current to pilot the feeder on the basis of an effective range of the current the coupon should receive. Laboratory tests confirmed the feasibility of such new approach. Modeling and test results are presented and discussed.
In presence of stray current interference due to DC transit systems, CP is operated at so-called “constant potential” condition. This technique consists of a continuous measurement of the pipeline potential by a fixed reference electrode, and the use of such measured potential to pilot the feeder dynamically, in order to maintain that potential constant. An accurate analysis of this technique reveals that what is maintained constant is IR drop in soil rather than the true potential of the structure. On the basis of this evidence, a new approach was investigated, consisting on two steps: the first was the measurement of the true potential by means of a corrosion coupon with an embedded reference electrode, to check protection conditions, and the second was the measurement of the coupon current. The innovation consists of the use of such current to pilot the feeder on the basis of an effective range of the current the coupon should receive. Laboratory tests confirmed the feasibility of such new approach. Modeling and test results are presented and discussed.
Product tags
Also Purchased
Picture for 98560 MEASUREMENTS OF OHMIC DROP FREE POTENTIAL
Available for download

98560 MEASUREMENTS OF OHMIC DROP FREE POTENTIAL IN THE PRESENCE OF STRAY CURRENT

Product Number: 51300-98560-SG
ISBN: 98560 1998 CP
Author: Luca Bertolini, Pietro Pedeferri, Bruno Bazzoni, Luciano Lazzari
$20.00
Picture for AC and DC Stray Current Mitigation and Corrosion Control for a New Urban Pipeline
Available for download

51312-01694-AC and DC Stray Current Mitigation and Corrosion Control for a New Urban Pipeline

Product Number: 51312-01694-SG
ISBN: 01694 2012 CP
Author: Dan Crabtree
Publication Date: 2012
$20.00