03714 FIELD EVALUATION OF CORROSION CONTROL USING REGENERATIVE BIOFILMS (CCURB)

Product Number: 51300-03714-SG
ISBN: 03714 2003 CP
Author: P. J. Arps, L-C. Xu, R. M. Green , T. K. Wood , F. B. Mansfeld , B. C. Syrett , J. C. Earthman
$0.00
$20.00
$20.00
Closed-loop sidestream systems that simulate the service water conditions at energy generating facilities are being used to evaluate the concept of corrosion control using regenerative biofilms (CCURB) at Three Mile Island Nuclear Power Station. These biological treatments are being developed as alternatives to the use of biocides and chemical inhibitors for controlling corrosion. Electrochemical impedance spectroscopy (EIS) measurements were performed on small metal disc specimens of mild steel, stainless steel, and cartridge brass under different flow conditions in service water inoculated with a consortium of adapted CCURB bacteria (test sidestream). A comparison of the electrochemical and SEM results for the test specimens with those for metal samples simultaneously exposed to unaltered service water (control sidestream) indicates that the CCURB bacteria reduced the corrosion rates of these materials under simulated service water conditions. Pitting analyses of the brass specimens verify the conclusions based on electrochemical results. The results obtained so far suggest that this “probiotic” approach to controlling corrosion in industrial settings may be possible. Keywords: corrosion control, biofilm, microbiologically influenced corrosion, EIS, localized corrosion
Closed-loop sidestream systems that simulate the service water conditions at energy generating facilities are being used to evaluate the concept of corrosion control using regenerative biofilms (CCURB) at Three Mile Island Nuclear Power Station. These biological treatments are being developed as alternatives to the use of biocides and chemical inhibitors for controlling corrosion. Electrochemical impedance spectroscopy (EIS) measurements were performed on small metal disc specimens of mild steel, stainless steel, and cartridge brass under different flow conditions in service water inoculated with a consortium of adapted CCURB bacteria (test sidestream). A comparison of the electrochemical and SEM results for the test specimens with those for metal samples simultaneously exposed to unaltered service water (control sidestream) indicates that the CCURB bacteria reduced the corrosion rates of these materials under simulated service water conditions. Pitting analyses of the brass specimens verify the conclusions based on electrochemical results. The results obtained so far suggest that this “probiotic” approach to controlling corrosion in industrial settings may be possible. Keywords: corrosion control, biofilm, microbiologically influenced corrosion, EIS, localized corrosion
PRICE BREAKS - The more you buy, the more you save
Quantity
1+
5+
Price
$20.00
$20.00
Product tags
Also Purchased
Picture for 03718 The Role of Ash Deposits in the High
Available for download

03718 The Role of Ash Deposits in the High Temperature Corrosion of Boiler Tubes

Product Number: 51300-03718-SG
ISBN: 03718 2003 CP
Author: Bernard S. Covino, Jr., James H. Russell, Stephen D. Cramer, Gordon R. Holcomb, Sophie J. Bullard, M
$20.00
Picture for 03719 NEW CORROSION PROTECTION METHODS
Available for download

03719 NEW CORROSION PROTECTION METHODS FOR EXISTING REINFORCED CONCRETE STRUCTURES

Product Number: 51300-03719-SG
ISBN: 03719 2003 CP
Author: Prof. Efim Ya. Lyublinski, Dr. Donald A. Kubik, Eng. Ronnie A. Singh
$20.00
Picture for 03717 Power Plant Iskenderun (Turkey)- Corrosion
Available for download

03717 Power Plant Iskenderun (Turkey)- Corrosion Protection Systems for the Flue Gas Desulphurization (FGD) Plant

Product Number: 51300-03717-SG
ISBN: 03717 2003 CP
Author: Steve Davies, Max Kaempffer and Wolfgang Berger
$20.00